Electrochemical measurements in various environments; Corrosion monitoring of carbon steel in deep underground environment

Taniguchi, Naoki; Nakayama, Masashi

Zairyo To Kankyo, 67(12), p.487 - 494, 2018/12

This article describes the current status of corrosion monitoring methods and examples of the measurement under deep underground environments for carbon steel overpacks for high-level radioactive waste disposal. Based on the studies on corrosion monitoring using AC Impedance technique, some of the typical measurement systems such as the electrodes arrangement are introduced. In-situ corrosion monitoring in engineering scale test is also being attempted using a deep underground research facility, and the measurement method and results are presented in this article.

Journal Articles

Electrochemical impedance analysis on solid electrolyte oxygen sensor with gas and liquid reference electrodes for liquid LBE

Adhi, P. M.*; Okubo, Nariaki; Komatsu, Atsushi; Kondo, Masatoshi*; Takahashi, Minoru*

Energy Procedia, 131, p.420 - 427, 2017/12

 Times Cited Count:0 Percentile:0.03(Energy & Fuels)

The ionic conductivity of solid electrolyte may insufficient, and the sensor output signal will deviate from the theoretical one in low temperature. The performance of oxygen sensor with Ag/air reference electrode (RE) and liquid Bi/Bi$$_{2}$$O$$_{3}$$ RE was tested in low-temperature LBE at 300$$sim$$450$$^{circ}$$C and the charge transfer reactions impedance at the electrode-electrolyte interface was analyzed by electrochemical impedance analysis (EIS). After steady state condition, both of the sensors performed well and can be used at 300$$sim$$450$$^{circ}$$C. Bi/Bi/Bi$$_{2}$$O$$_{3}$$ RE has lower impedance than Ag/air RE. Therefore, the response time of the oxygen sensor with Bi/Bi/Bi$$_{2}$$O$$_{3}$$ RE is faster than the oxygen sensor with Ag/air RE in the low-temperature region.

Journal Articles

Systematic calibration of beam position monitor in the high intensity proton accelerator (J-PARC) linac

Sato, Susumu; Igarashi, Zenei*; Lee, S.*; Tomisawa, Tetsuo; Hiroki, Fumio; Kishiro, Junichi; Ikegami, Masanori*; Kondo, Yasuhiro; Hasegawa, Kazuo; Ueno, Akira; et al.

Proceedings of 22nd International Linear Accelerator Conference (LINAC 2004), p.429 - 431, 2004/00

As a joint project of KEK and JAERI, a MW class of high intensity proton accelerator (J-PARC), consisting of Linac, 3 GeV-RCS, 50 GeV-MR, is under construction at Tokai, Japan. For this accelerator, it is required to minimize the beam loss (typically, lower than 0.1$$sim$$1 W/m at the linac). To achieve the requirement, beam trajectory needs to be controlled with accuracy of some 100 micro-meter. The first stage of the acceleration (up to 181 MeV during the first stage of construction) is done by linac. The beam position monitor (BPM) in the linac utilizes 4 strip-line pickups (50 ohm) on the beam transportation chamber. In this paper, systematic calibration of the BPM is described.

JAEA Reports

In-situ measurement of zircaloy corrosion rate in high temperature, high pressure water

Suzuki, Motoe

JAERI-Research 94-022, 36 Pages, 1994/10

JAERI-Research-94-022.pdf:1.28MB

no abstracts in English

JAEA Reports

Application of AC-impedance method on determination of corrosion rate of metals

Suzuki, Motoe

JAERI-M 87-095, 34 Pages, 1987/07

JAERI-M-87-095.pdf:0.93MB

no abstracts in English